Tri Star CNC Services helps you identify FANUC servo drive errors by translating alarm codes and lay out a plan for repairing your CNC machine controls. Fanuc-15i PRM 3028 Fanuc-16i/18i/21i PRM 4028 Output restriction pattern setting Fanuc-15i PRM 3029 Fanuc-16i/18i/21i PRM 4029 Output restriction value (c)The parameters specific to the motor are not correctly. Refer to 'FANUC AC SPINDLE MOTOR i series Parameter Manual (B-65280EN),' and check the motor-specific parameters. Alarm Code 03. OPERATOR'S MANUAL. B-83124EN-6/01 R-30.A/R-30.A Mate CONTROLLER! Alarm Code List (For series 7DA4/7DA5) Or i gi nal Inst r uct i ons Before using the Robot, be sure to read the 'FANUC Robot Safety Manual (B-80687EN)' and understand the content. No part of this manual may be reproduced in any form. All specifications and designs are subject to change without notice. FANUC ERROR codes and alarms for Fanuc drives: Check for LED’s lit on drive control PCB’s or numbers/letters such as AL.11 in the multi section 7 segment LED displays. DC AXIS unit alarms.
FANUC Alpha Servo Amplifier Alarm and Error Codes
Nicelabel pro 6 keygen. The following alarm codes pertain to FANUC Alpha SVM series (part numbers started from A06B-6079, A06B-6080, A06B-6096, and A06B-6097). Knowing your error code could help us provide you with the fast and precise evaluation for repair or exchange services.
Please contact us for free consultation about any of the following error codes, or any other problems with your FANUC servo units. Call 630-616-0039 or fill up a contact form.
Alarm Code | Description of Alarm/Error |
---|---|
1 | Inverter: Internal cooling fan stopped |
2 | Inverter: Control power supply under voltage |
5 | Inverter: DC link under voltage |
6 | Inverter: Overheat |
8 | Inverter: DC link current alarm (L axis) |
8. | Inverter: IPM alarm (L axis) |
9 | Inverter: DC link current alarm (M axis) |
9. | Inverter: IPM alarm (M axis) |
Blinking | Inverter: abnormal control power supply |
A | Inverter: DC Link Current alarm (N axis) |
A. | Inverter: IPM alarm (N axis) |
b | Inverter: DC Inverter: Control Command Failure |
c | Inverter: DC Inverter: Control Command Failure |
d | Inverter: DC Inverter: Control Command Failure |
F | Inverter: cooling fan stopped of the radiator |
P | Inverter: Communication error between amplifier and module |
U | Inverter: FSSB communication error (COP10B) |
L | Inverter: FSSB communication error (COP10A) |
Fanuc Error Codes Pdf
FANUC Servo Amplifier Series A06B-6089 and A06B-6090 Alarm Codes
The alarms and error code below are for FANUC Servo Amplifier Series A06B-6089 and A06B-6090. If an alarm condition occurs, the 7-segment LED indicator on the amplifier will behave according to the table below.
Alarm Code | Type |
---|---|
1 | Over Voltage alarm (HV) |
2 | Low control power voltage alarm (LV) |
3 | Low DC link voltage alarm (LVDC) |
4 | Regenerative discharge control circuit failure alarm (DCSW) |
5 |
Over regenerative discharge alarm (DCOH) |
7 | Dynamic brake circuit failure alarm (DBRLY) |
8 | L-axis over current alarm (HCL) |
9 | M-axis over current alarm (HCM) |
6 | L and M axis over current alarm (HCM) |
8 | L-axis IPM alarm (IPML) |
9 | M-axis IPM alarm (IPMM) |
b | L and M axis IPM alarm |
Trips | Circuit breaker |
FANUC A06B-6114, A06B-6117 Series Alarms and Error Codes
![Error Error](https://motioncontrolsrobotics.com/wp-content/uploads/2018/01/alarm-history.png)
The alarms and error codes below are FANUC Alpha I Servo Amplifier Module Alarms covering the series of FANUC A06B-6114, A06B-6117 Alpha servo amplifiers.
Alarm Code | Description of Alarm/Error |
---|---|
1 | Inverter: Internal cooling fan stopped |
2 | Inverter: Control power supply under voltage |
5 | Inverter: DC link under voltage |
6 | Inverter: Overheat |
F | Inverter: cooling fan stopped of the radiator |
P | Inverter: Communication error between amplifier and module |
8 | Inverter: DC link current alarm |
8.9.A |
Inverter: IPM alarm |
8.9.A | Inverter: IPM alarm (OH) |
bcd |
Inverter: IPM alarm (OH) |
Request a Free Consultation